Dreure's single-use sampling system is designed for transferring the sample from reactor to sampling bags through path. And multi path can be reached with small vessels of sampling bags. As well, the Pinch and Cut separation device to ensue the sterility of whole sampling process.
· The co-extruded film for biopharm applications features exceptional mechanical strength, high barrier properties, and excellent chemical resistance.
· With a total thickness of 0.325 mm, the main material of the film is PE and EVOH.
· ULDPE is the contact layer and fully complies with standard pharmacopoeia regulations, delivering superior cleanliness and robust chemical resistance.
· The EVOH core layer serves as a high-performance barrier, offering exceptional resistance to gas permeation, including O2, CO2, and H2O.
· Indicated volume 5ML-3L, customized
Film SF001

◆ Appearance: 100% visual inspection (lamp inspection)
◆ Seal Integrity: 100% leak testing (integrity testing)
◆ Low particle and free of endotoxin
◆ Biocompatibility: Complies with USP<87>& USP<88>Class VI
◆ Extractables & Leachables (E&L): Complies with standard regulatory requirements
Upstream cell culture process:
- Storage and transfer of media and buffers for seed culture,
- Feedstock replenishment, and other purposes;
- Collection, temporary storage, and transfer of cell harvests;
Downstream purification process:
- Collection and temporary storage of target molecules;
- Storage of buffers, acids, and bases during the purification process;
- temporary storage and inter-process transport of intermediates during the purification process;